Company logo of Berger Maritiem featuring a green leaf, symbolizing global sustainable maritime innovation and solutions.
Small logo version of Berger Maritiem featuring a green leaf, symbolizing global sustainable innovation and solutions in the maritime sector.
Illustration of a waste heat recovery system (WHRS) with a control panel and pipework in a ship's engine room.

How Is Electricity Generation From Waste Heat Accounted for in EEDI and EEXI Calculations?

Electricity production from waste heat can, under the applicable IMO conditions, be included as an effective reduction in auxiliary electrical power in the calculation of the Energy Efficiency Design Index (EEDI) or Energy Efficiency Existing Ship Index (EEXI). A waste heat recovery system (WHRS) uses heat from sources such as exhaust gases or engine cooling water to generate electricity. In an installation based on the Organic Rankine Cycle (ORC), this takes place through a separate thermodynamic process.

For EEDI and EEXI, however, the maximum generator power or electricity production measured during operation is not automatically used. The contribution must be determined under prescribed ship performance conditions in accordance with the applicable guidelines of the International Maritime Organization (IMO). The relevant power conversion and the power needed to operate the system itself must also be accounted for. For electricity generation from high-temperature waste heat, IMO circular MEPC.1/Circ.896 describes a specific method using the effective power contribution PAEeff. Whether an individual ORC design falls within that method must be established from the actual heat sources and installation configuration.

The calculated contribution is then accounted for in accordance with the applicable index formula and must be supported by adequate technical evidence and verified. An operating ORC installation therefore does not automatically mean that its full stated electrical power may be included as an improvement in EEDI or EEXI.

What Is the Difference Between EEDI, EEXI and Actual WHRS Production?

EEDI and EEXI are technical energy efficiency indices under MARPOL Annex VI for ships to which the relevant requirements apply. EEDI addresses the technical energy efficiency of relevant new ships, while EEXI allows a comparable assessment for existing ships within its scope. Both indices link the CO2 emissions attributable to energy supply, calculated under the applicable method, to a prescribed measure of transport work. Engine power, specific fuel consumption, CO2 conversion factors, ship capacity and reference speed are among the parameters included.

Under the applicable calculation rules, the index is expressed in grams of CO2 per unit of capacity and nautical mile. For many cargo ships, the capacity measure is based on deadweight in tonnes, while a different prescribed capacity measure may apply to certain other ship types. The attained index value is not a direct measurement of annual CO2 emissions. The calculation uses technical reference conditions and prescribed parameters to assess energy efficiency in a standardized way.

This distinction is important for electricity production from waste heat. An ORC installation does not continuously deliver the same power during actual operation. Available exhaust gas and cooling-water heat change with engine load, while condenser conditions and control settings also affect electrical output. During prolonged part-load operation, the ORC may deliver less electricity than at a higher engine load. In other operating modes, more heat may instead be available, provided that the heat exchangers, expander and generator function within their permitted operating range.

However, the EEDI or EEXI calculation does not simply use the average generator power across all voyages. The effective electrical contribution is determined in accordance with the technical calculation framework applicable to the index concerned. The power used in the index calculation may therefore differ from the power delivered on a particular voyage. The maximum stated module output also need not correspond to the power available under the prescribed reference conditions.

A lower calculated EEDI or EEXI value therefore does not by itself establish annual electricity generation, fuel savings or CO2 reduction during operation. For that purpose, the actual operational and load profile must be assessed separately.

Which IMO Category Covers Electricity Production from Waste Heat?

IMO circular MEPC.1/Circ.896 of 14 December 2021 provides supplementary guidance on calculating and verifying the effects of innovative energy efficiency technologies on EEDI and EEXI. The guidelines distinguish between technologies that directly affect the ship's energy efficiency, measures that reduce the required propulsion power and systems that produce electricity. These different effects are not automatically accounted for in the index in the same way.

Technologies whose effect is already included in propulsion performance and reference speed are treated under category A. For certain measures that reduce propulsion power and must be assessed separately, the guidelines use category B and the effective power contribution Peff. Innovative electricity-producing technologies belong to category C. Their contribution is expressed under the relevant method as an effective reduction in auxiliary power, denoted by PAEeff.

Within category C, the IMO distinguishes two subcategories. For category C-1, an availability factor feff of 1.00 applies. For category C-2, availability depends on the relevant conditions and is treated differently.

Annex 2 of MEPC.1/Circ.896 expressly covers electricity generation from high-temperature waste heat under category C-1. Among other arrangements, the guidelines describe a system that transfers heat through a heat exchanger to a heat engine driving a generator. Electricity production through a separate exhaust gas power turbine and combinations of both principles are also addressed. An ORC can operate according to the first principle. Exhaust gas heat is then transferred, for example, to the organic working fluid through a heat exchanger and, where present, an intermediate circuit. The expander then drives a generator.

However, the C-1 methodology is described specifically for high-temperature waste heat recovery. The guidelines also name engine cooling water as a possible source of recovered engine heat, but do not establish that the method applies to every ORC that uses only relatively low-temperature heat without further assessment. Particularly for a low-temperature ORC, it must therefore be established whether the specific system configuration can be assessed within the existing guidelines. It must also be clear what technical substantiation the verifier requires for this.

The function of the recovered power is also important. If the heat is used to deliver mechanical power directly to a propulsion shaft, this effect is not automatically treated under the C-1 method for electricity production. The guidelines distinguish between electrical generation and recovered mechanical power that may already be reflected in reference speed.

For the C-1 heat recovery described, feff = 1.00 applies. This is a prescribed factor within the index methodology and does not mean that the WHRS continuously operates at maximum output or is always available during actual operation. The category therefore determines how the energy efficiency contribution is treated in the index. Before ORC power can be included, it must be clear that the selected installation fits within the applicable method and how the effective electrical power contribution is established.

How Is the Effective Electrical Power PAEeff Established?

For electricity-producing waste heat recovery, MEPC.1/Circ.896 uses the effective power contribution PAEeff. This quantity describes the reduction in total auxiliary electrical power under the ship performance conditions applicable to the index calculation. The guidelines distinguish between the power produced as determined under their method and the power needed to operate the recovery system itself.

The starting point is:

PAEeff = P'AEeff − PAEeff_loss

Here, P'AEeff is the power from waste heat recovery determined in accordance with the guidelines. PAEeff_loss represents the power needed to run the WHRS, including its pumps and other equipment.

The guidelines also define P'AEeff through a separate conversion:

P'AEeff = We / ηg

Here, We is the calculated electrical power generated by the waste heat recovery system and ηg is the weighted average generator efficiency as used in the IMO methodology.

This conversion is important in the interpretation of technical power specifications. The power stated by a supplier as gross or net ORC electrical output must not be equated with P'AEeff or PAEeff without further assessment. The effective power contribution follows from the specific definitions and calculation steps in MEPC.1/Circ.896. It therefore cannot be established solely by simply subtracting an estimated pump power from a brochure rating.

In an ORC, the installation's own energy consumption is relevant because the working-fluid pump needs electricity to circulate the working fluid through the cycle. Depending on the system arrangement, intermediate-circuit pumps and other necessary auxiliary equipment may also require electrical power. This consumption cannot simultaneously be regarded as a saving in the existing energy supply. It must be accounted for under the applicable definition of PAEeff_loss.

The electrical system boundary must be clear. An ORC module may have a stated net output that already allows for the power drawn by certain pumps, while additional equipment is installed separately on board. The calculation must therefore distinguish between electricity production under the IMO definition and the necessary power deducted separately under the same method. The same auxiliary consumption must not be counted twice as a loss.

MEPC.1/Circ.896 also describes the contribution for the power generated under the relevant ship performance condition and supplied to the main switchboard. The guidelines take this power into account regardless of its subsequent use on board, subject to the method's treatment of the power required to run the WHRS. This approach differs from an annual operational calculation, in which electrical demand is assessed separately for each operating period. For EEDI and EEXI, the specific conditions of the index methodology concerned apply.

For category C-1, PAEeff is then included in the index calculation with feff = 1.00. However, the effective value must still be established under the prescribed reference conditions and verified using adequate technical evidence. PAEeff is therefore not an arbitrarily selected generator power, but a specific calculated quantity. It allows electricity production from waste heat to be accounted for in the energy efficiency index under the applicable IMO method.

Which Heat Source and Engine Conditions Apply to the Index Calculation?

WHRS electricity production depends on the heat available from the relevant engines. For the index calculation, heat-source data must therefore be used that correspond to the engine and ship performance conditions of the applicable calculation framework. For exhaust gas heat, gas temperature, mass flow rate and how far the gas may be cooled are particularly important. Together with the properties and performance of the heat exchanger, they determine how much thermal power can be transferred to the WHRS.

For the determination of PAEeff, MEPC.1/Circ.896 explicitly names the exhaust gas conditions, the waste heat recovery system configuration and the performance of the components concerned. For design verification, the guidelines describe, among other data, main-engine data at 75% of the main engine's maximum continuous rating (MCR). For auxiliary engines involved, the conditions under which specific fuel consumption was determined may also be relevant.

The effect of intake air temperature on the exhaust gas data may also form part of the substantiation. The guidelines name various possible ambient conditions for this purpose. These data belong to the EEDI reference framework and the verification method described. They do not constitute a general requirement to assess every WHRS at exactly 75% MCR under all conditions.

EEXI has its own rules for the relevant engine power. If an overridable engine or shaft power limitation is applied under the EEXI conditions, the lower of 83% of the limited installed power and 75% of the original installed engine power may, for example, be decisive for the calculated propulsion power. This rule applies to the relevant power-limited configuration. It must not be used without further assessment as a general EEXI operating point for every engine or WHRS.

If the EEXI calculation is based on permitted engine power values that differ from those of the original design, it must therefore be established how the WHRS heat-source data used relate to that calculation framework. The maximum thermal power available from the exhaust gas from the original engine need not, after all, correspond to the heat conditions relevant to the applicable EEXI calculation.

The heat exchangers must also perform as required under the operating conditions examined. Heat extraction remains limited by the available heat transfer, permitted exhaust back pressure and temperature requirements of the exhaust gas path. If an ORC uses different heat sources, their properties must remain separately identifiable. Exhaust gas heat and engine cooling-water heat may provide different levels of thermal power and different temperatures at the same engine load.

An intermediate circuit, where fitted, transfers heat from the original source to the ORC module. The heat exchangers and necessary temperature differences then determine how much heat can ultimately be supplied to the organic working fluid. Condenser conditions also affect electricity production. At a higher condensing temperature, the expander may deliver less mechanical work. The cooling conditions used must therefore be technically substantiated and suit the ORC operating point to which the calculation relates.

The index calculation must ultimately be based on mutually consistent engine, heat source, component and cooling conditions. A favourable value for the thermal power available from the exhaust gas from one operating mode must not be combined without further substantiation with ORC performance achievable only under different conditions.

How Is the WHRS Contribution Accounted for in the EEDI and EEXI Formula?

The EEDI and EEXI formulae link the energy-related CO2 contributions determined under the method to a prescribed measure of the ship's transport work. The relevant propulsion power, auxiliary energy supply, specific fuel consumption and associated CO2 conversion factors are among the parameters included in the numerator. The denominator contains the applicable ship capacity, reference speed and relevant correction factors.

For a WHRS treated under category C-1, the effective electrical power contribution is accounted for as a separate reduction within the prescribed numerator. The PAEeff value is therefore not subtracted directly from the final EEDI or EEXI value. The effective power contribution is first linked to the fuel consumption and CO2 conversion parameters that the index formula prescribes for it.

For category C, MEPC.1/Circ.896 describes the power contribution in combination with the factors feff, SFCAE and CFAE. SFCAE represents the relevant specific fuel consumption for auxiliary electricity generation. CFAE is the associated CO2 conversion factor. For category C-1, feff = 1.00 applies. The effective WHRS power contribution is thus converted into a reduction in the CO2-related contribution calculated under the index methodology.

The exact treatment must correspond to the complete applicable EEDI or EEXI formula. After all, not every ship configuration uses the same simplified distribution between main- and auxiliary-engine power. If, for example, some of the normal electrical energy supply is delivered through a shaft generator, the main engine's fuel consumption and CO2 factors may also be relevant under the rules concerned. With electric propulsion assistance, additional provisions may also apply to the combination of propulsion and electrical power. The different power contributions must then be reconciled in accordance with the prescribed method.

The other ship data also remain decisive for the calculated index value. An identical effective WHRS power contribution does not automatically result in the same EEDI or EEXI improvement for two different ships. The original index value, reference speed, capacity, fuel data and applicable correction factors may differ between ships. A general percentage improvement in EEDI or EEXI therefore cannot be derived from a particular ORC generator power without a ship-specific calculation.

If the contribution is correctly accounted for under the applicable method, the attained index value may decrease. In this context, a lower value means more favourable technical energy efficiency under the prescribed calculation method.

Why Must Different Energy-Saving Contributions Be Assessed Separately?

A ship may combine different energy efficiency technologies that affect the required propulsion power, available engine heat or electrical energy supply. These measures may affect each other and are not automatically treated in the same way within the IMO methodology. A measure whose effect is included directly in propulsion performance may be accounted for under category A. For certain measures that reduce propulsion power and must be assessed separately, the guidelines use category B and the effective power contribution Peff.

An electricity-producing WHRS suitable for this treatment is addressed under category C using PAEeff. The distinction between these categories is important when several technologies are applied to the same ship. An Energy Saving Device may, for example, reduce the required propulsion power. The engine may consequently operate at a different load for the same ship performance. If that engine simultaneously supplies heat to the WHRS, the heat available to the WHRS may also change.

The effects on waste heat must therefore not be determined by assuming the original engine operating point without further assessment and then adding the separate savings to it. At the same time, it must be established how the different measures have been accounted for in the index under the IMO methodology. Not every propulsion improvement yields a separate Peff term. Certain effects may already be reflected in the reference speed or propulsion power used within the calculation framework.

If an effect has already been accounted for in propulsion performance, the same improvement must not be counted again in full as an independent power reduction. The combination of WHRS electricity, shaft generators and electrical propulsion assistance may also make the energy balance more complex. The requirements therefore contain specific provisions for the way different power contributions are accounted for.

A measure that reduces the electrical auxiliary energy requirement must not also be included as a separate reduction in main propulsion power without further substantiation. It must therefore be clear which energy flow is affected by each technology and where that effect is accounted for under the index formula.

Additional caution is needed with diesel-electric, hybrid and other non-conventional propulsion configurations. MEPC.1/Circ.896 itself indicates that, for certain such configurations, the general formula and supplementary guidelines may provide insufficient detail on calculation and verification. The correct treatment must therefore be established for the propulsion and electrical architecture actually used. The applicable IMO guidelines and the assessment by the verifier concerned must be included.

What Technical Data Are Needed to Substantiate the WHRS Contribution?

An effective electrical WHRS contribution must be traceable to the technical characteristics and operating conditions of the relevant system. It must first be clear which heat sources are used and how they are connected to the waste heat recovery system. The configuration of heat exchangers, intermediate circuits, pumps, heat engines and generators determines how much heat is available and how it is converted into electrical power.

For an ORC, performance data must relate to the selected organic working fluid, heat exchangers, expander and condenser. The calculation must show what power the installation can deliver under the relevant heat and cooling conditions. It must also be clear where in the system the electrical power is measured or calculated. Gross generator power, net module power and an effective PAEeff contribution under the IMO methodology describe different quantities.

The technical data must therefore provide sufficient insight into the calculated electrical output, prescribed power conversion and power required to operate the WHRS. For design verification, MEPC.1/Circ.896 describes, among other information, diagrams and specifications of the waste heat recovery system. A process flow diagram and a piping and instrumentation diagram can provide insight into the heat and energy flows. The calculation of the effective reduction in auxiliary power and the associated EEDI calculation result also form part of the substantiation described.

The verifier may need additional data on the engines and heat sources concerned. The guidelines identify exhaust gas data at the relevant engine conditions, including gas temperature, flow rate, any bypass flows and the effect of different intake air temperatures. For heat transfer through a heat exchanger, data on the calculated heat absorption and the condition of the medium receiving this heat may also be needed.

For this purpose, the guidelines describe, among other information, steam production data for steam-based recovery systems. However, for an ORC with an organic working fluid, the substantiation must correspond to the thermodynamic process actually used and to the data that the verifier accepts for that design. The fact that the guidelines refer to steam data for a particular component does not mean that these can be used without further adaptation as a measured quantity for every organic cycle.

The thermal and electrical performance must nevertheless remain sufficiently verifiable. The origin of the data used is also important. A general product specification giving only the maximum generator output does not necessarily demonstrate how much power is available at the relevant engine operating point. Suitable performance data for the complete WHRS configuration are needed for that purpose.

It must also be established whether the data used correspond to the installation actually present on the ship. If, for example, a different heat exchanger, intermediate circuit or generator design is used, the original performance data may no longer be sufficiently representative. Technical substantiation therefore serves a different purpose from a commercial power specification. It must make it possible to verify how the available engine heat, installation performance and relevant system losses lead to the calculated PAEeff value under the IMO methodology.

How Is Electricity Production from Waste Heat Verified for EEDI?

For EEDI, the technical energy efficiency of a relevant new ship is assessed at the design and delivery stages. If electricity production from waste heat is included as an innovative energy efficiency technology, the contribution must be substantiated under the applicable calculation and verification procedure.

For the calculation, the 2022 Guidelines on the Method of Calculation of the Attained Energy Efficiency Design Index (EEDI) for New Ships apply, as adopted by resolution MEPC.364(79) and amended by, among other resolutions, MEPC.410(84) of 2026. For survey and certification, the 2026 Guidelines on Survey and Certification of the Energy Efficiency Design Index (EEDI), adopted by resolution MEPC.411(84), apply. These guidelines replace the earlier EEDI verification guidelines of 2022, as amended.

The supplementary treatment of innovative electricity production from waste heat is set out in MEPC.1/Circ.896. This circular must be applied together with the applicable EEDI guidelines and does not replace the general calculation or certification framework. During design verification, technical evidence is provided for the proposed WHRS configuration. The relevant data are included in or linked to the EEDI Technical File, in which the calculation of the attained EEDI is documented.

It must be clear how the effective electrical power contribution has been established and which engine, heat source and component data have been used for this purpose. The calculated contribution is then assessed in conjunction with the other EEDI parameters. These include the relevant engine power values, fuel consumption data and prescribed ship performance conditions.

For final verification, MEPC.1/Circ.896 states that the effective contribution of a WHRS should be verified using shop test results for the principal system components and, where possible, at sea trials. This does not mean that every WHRS can be verified solely through one direct measurement of net generator power during the sea trial.

For some components, such as an exhaust gas heat exchanger, it may be difficult to establish full performance under representative heat-source conditions during a separate factory test. The guidelines therefore also describe an approach in which heat transfer is assessed from sea trial measurements, with the results corrected to the relevant reference conditions. For steam-based recovery, steam output and temperature are among the parameters named for this purpose.

For an ORC with a different thermodynamic process, it must be established which data and verification method correspond to the actual installation and the applicable guidelines. The method used and any corrections must be sufficiently verifiable. A technical test under different engine or cooling conditions must not be equated with performance at the operating point specified for the calculation without appropriate substantiation.

The verifier's role remains decisive. The Administration or an organization authorized for this purpose must be able to assess whether the technical documentation, calculations and test results provide sufficient evidence for the stated effective power contribution. Successful commissioning of an ORC therefore does not automatically constitute complete proof that a particular PAEeff value may be included in EEDI.

Formal verification must confirm that the WHRS contribution has been calculated under the applicable IMO framework, sufficiently substantiated and correctly accounted for in the attained EEDI.

How Does the Treatment of WHRS Electricity Differ for EEXI?

EEXI assesses the technical energy efficiency of existing ships to which the relevant requirements apply. The calculation method is set out in the 2022 Guidelines on the Method of Calculation of the Attained Energy Efficiency Existing Ship Index (EEXI), adopted by resolution MEPC.350(78). For survey and certification, the 2022 Guidelines on Survey and Certification of the Attained Energy Efficiency Existing Ship Index (EEXI), adopted by resolution MEPC.351(78), apply.

Under the circular's application provisions, the supplementary guidelines in MEPC.1/Circ.896 are also intended for innovative energy efficiency technologies in EEXI. Although the text of this circular mentions only EEDI in several places, the treatment described is intended for both indices to the extent applicable. The EEXI verification guidelines explicitly confirm that MEPC.1/Circ.896 must be applied where relevant.

The basic principle for the effective electrical contribution of a suitable WHRS therefore need not differ substantially from that for EEDI. The main difference lies in the ship's existing technical documentation and the specific parameters and verification routes applicable to EEXI. An existing ship may already have a WHRS. In that case, it must be established which original performance data, diagrams and test results are available and whether they are suitable for use under the relevant EEXI conditions.

A WHRS may also have been retrofitted. It must then be assessed whether the selected installation can be accounted for under the applicable IMO methodology and which additional technical data are needed for this. The calculation must not automatically be based on a previously stated maximum generator output. The heat-source conditions and effective electrical contribution must correspond to the engine and ship performance conditions applicable under the EEXI calculation framework.

An important consideration is the propulsion-engine power used for the EEXI calculation. If an overridable engine or shaft power limitation has been applied under the relevant rules, the power used in the calculation may differ from the original rated engine power. The heat-source data used for the WHRS must be sufficiently consistent with this. It is not sound practice to combine exhaust gas heat from an originally higher engine operating point with an EEXI calculation based on a different relevant engine power without further assessment.

The technical condition and configuration of an existing WHRS must also correspond to the data on which the calculation is based. A historical power specification may be insufficient if the engine installation, heat exchangers or ORC configuration have since been modified. Some ships already have a verified attained EEDI. The EEXI guidelines allow an existing attained EEDI to be used as the attained EEXI if the applicable conditions and limits are met.

However, this is not general permission to account for a previously calculated WHRS contribution again in a modified EEXI calculation without further checks. The applicable verification route and required technical data must therefore be established for the ship concerned. A suitable ORC installation can thus make a favourable contribution to the calculated EEXI. This is possible only if the effective power contribution has been established under the applicable conditions and guidelines and sufficiently verified.

Why Does the EEDI or EEXI Contribution Not Equal Annual Fuel Savings?

The effective WHRS power contribution for EEDI or EEXI is determined under prescribed technical calculation conditions. Actual fuel savings, by contrast, arise during operation, as the ship operates at varying engine loads, cooling conditions and electrical energy requirements. An ORC delivering a particular effective power under the index conditions may produce more or less electricity in other operating modes. The installation may also be temporarily out of service because of maintenance, insufficient heat supply or other operational limitations.

The calculated PAEeff value must therefore not be multiplied by all hours under way in a year without further substantiation to predict actual electricity production. Nor does the availability factor feff = 1.00 for category C-1 prove that the WHRS continuously delivers the calculated power during every voyage. This factor has a specific function within the index methodology.

To estimate annual output reliably, the available heat, cooling conditions and electrical demand during the relevant operating periods must be assessed together. Start-up, downtime, output reduction and the installation's own energy consumption also affect net electricity generation. Actual fuel savings then require a comparison of the ship's energy supply without and with a WHRS.

If a generating set needs to deliver less power because of the WHRS electricity generated, fuel consumption may decrease. The size of this reduction depends on the original and new engine loads and the corresponding fuel consumption curve. Shutting down a generating set completely may yield a different result from partly unloading several running engines. Sufficient electrical power reserve must also remain available.

If the ORC uses heat from the same engines whose load is reduced by electricity production, the available heat supply may also change. Electrical and thermal operating conditions must then be assessed together. The effect of the WHRS on other ship systems may also be relevant. An additional exhaust gas heat exchanger may, for example, increase back pressure and thereby affect engine operation. Existing users of the recovered heat may also be affected if heat is used for another application.

The necessary electrical consumption of pumps and cooling arrangements must also be correctly accounted for in the complete energy balance. These effects may be decisive for the amount of fuel actually saved, but are not automatically all reflected in the PAEeff value established for the index.

EEDI and EEXI therefore assess technical energy efficiency under a prescribed calculation method. Actual operational savings must be established separately on the basis of the operational profile, the energy produced and the change in engine dispatch. A lower EEDI or EEXI value due to waste heat recovery may therefore demonstrate a favourable technical contribution. However, a fixed annual fuel or CO2 saving is not thereby guaranteed.

When May Electricity Production from Waste Heat Be Included in EEDI or EEXI?

The first step in accounting for WHRS electricity is to establish whether the ship falls within the scope of EEDI or EEXI and identify the applicable calculation and verification guidelines. It must then be established whether the selected waste heat recovery system can be treated as an innovative electricity-producing energy efficiency technology under the applicable IMO methodology.

For electricity production from high-temperature waste heat recovery, MEPC.1/Circ.896 provides the C-1 methodology described. Whether a specific ORC design falls within it must be assessed from the heat sources actually used, installation configuration and conditions of the applicable verification framework. The effective power contribution PAEeff is then determined. The calculation accounts for the electrical output determined under the guidelines, the prescribed conversion using generator efficiency and the power needed to run the WHRS.

The contribution must be based on engine and heat-source conditions suited to the index calculation concerned. The exhaust gas temperature, mass flow rate, heat exchanger and ORC performance data must be sufficiently consistent with one another. The effective power contribution is then accounted for in the applicable EEDI or EEXI formula, using the prescribed fuel consumption and CO2 conversion parameters.

Other energy efficiency technologies and the electrical system configuration must also be included correctly. Effects already accounted for in the relevant propulsion power or reference speed must not be counted again as separate savings without further substantiation. Finally, the technical substantiation must meet the applicable verification conditions. Diagrams, engine and heat-source data, component performance, calculations and relevant test results must be available in enough detail for the verifier to check them.

An ORC may therefore be technically suitable for electricity production while a separate assessment is needed to establish what power contribution may be included in EEDI or EEXI. If the application falls within the method concerned and the effective contribution has been sufficiently demonstrated, electricity production from waste heat may favourably affect the calculated index value.

That contribution is then not based on an arbitrarily stated generator power or measured annual electricity production. It is based on a power value supported by technical evidence under the applicable IMO calculation and verification rules. In this way, the distinction is maintained between the electricity a WHRS produces during actual operation and the effective power that can be accounted for in the EEDI or EEXI calculation under the IMO methodology.

This Article in the Series

The contribution of WHRS electricity to EEDI and EEXI is determined under prescribed technical reference conditions. In this context, a different fuel or engine configuration may affect the available heat and calculated electrical output. During operation, actual fuel savings are what matter, as discussed in monitoring the contribution of waste heat recovery to CII through the SEEMP. This distinction between technical index calculations and operational performance forms part of the regulations for and assessment of WHRS installations.