Why Does Waste Heat Recovery Affect EU ETS and FuelEU Maritime Differently?
Author: Jeroen Berger • Publication date:
Waste heat recovery can reduce a ship's fuel consumption and greenhouse gas emissions, but these savings are assessed differently under EU ETS and FuelEU Maritime. A waste heat recovery system (WHRS) uses heat from sources such as exhaust gases or engine cooling water to supply electricity or useful heat. If this reduces fuel consumption, it can also reduce the emissions for which allowances must be surrendered under the EU Emissions Trading System (EU ETS).
FuelEU Maritime, by contrast, assesses the annual average greenhouse gas intensity of the energy used, expressed in grams of CO2 equivalent per megajoule (g CO₂e/MJ). When the relative shares of the energy sources and the applicable emission factors remain the same, a reduction in energy use does not automatically lower this intensity. Lower energy use can, however, change the magnitude of the FuelEU compliance balance. The same technical fuel savings may therefore directly reduce the allowances required under the EU ETS, while under FuelEU Maritime an existing compliance deficit or surplus may become smaller without the intensity requirement automatically being met. When the WHRS does not reduce consumption of different fuels in the same proportions, the average FuelEU intensity may also change.
To assess these effects correctly, the fuel actually saved, the relevant emissions accounting methods, the geographical scope and the separate calculation rules of the two systems must be clearly distinguished.
Why Do EU ETS and FuelEU Maritime Assess Different Quantities?
EU ETS and FuelEU Maritime are both intended to reduce greenhouse gas emissions from maritime transport. However, the two regulatory frameworks use different principles and calculation methods for this purpose. The EU ETS requires allowances to be surrendered for greenhouse gas emissions within its scope. The quantity of those emissions determines the number of allowances to be surrendered.
When a ship consumes less fuel and consequently reduces greenhouse gas emissions covered by the EU ETS, fewer allowances may be required. The size of this reduction depends on the fuel saved, the emissions concerned and the system's geographical scope.
FuelEU Maritime uses a different metric. Regulation (EU) 2023/1805 sets limits on the annual average greenhouse gas intensity of the energy used on board within its scope. The calculation includes relevant emissions from producing and supplying the energy and from using it on board. This approach is known as well-to-wake and covers both the well-to-tank and tank-to-wake stages. Greenhouse gas intensity is expressed in grams of CO2 equivalent per megajoule of energy used, or g CO₂e/MJ.
The key difference is therefore that the EU ETS accounts for the total emissions within its scope, while FuelEU Maritime sets a limit on average greenhouse gas emissions per unit of energy used. For waste heat recovery, this may lead to different outcomes. When a WHRS reduces fuel consumption, total greenhouse gas emissions may decrease. If the proportions of the energy carriers used remain the same and the applicable emission factors do not change, average emissions per megajoule also remain the same.
In that case, total emissions fall together with energy use, without greenhouse gas intensity changing. The fuel saving is real, but does not automatically lead to a lower FuelEU intensity. This does not mean that waste heat recovery has no effect under FuelEU Maritime. Alongside average intensity, the regulation also uses a compliance balance. The amount of energy used within the scope of the regulation also enters that calculation.
Lower energy use may therefore reduce the magnitude of an existing compliance deficit or surplus, even when average greenhouse gas intensity remains the same. The different outcomes therefore do not arise because the physical energy savings differ under EU ETS and FuelEU Maritime. The difference is caused by the quantities the two regulatory frameworks assess and the way energy use is accounted for in them.
How Does Waste Heat Recovery Lead to Fuel Consumption Actually Avoided?
Before the effects on EU ETS and FuelEU Maritime can be established, it must be clear how much fuel is actually saved through waste heat recovery. The rated power of a WHRS alone provides insufficient information for this purpose. A waste heat recovery system can use available heat directly for a suitable thermal application or convert it into electricity through a thermodynamic process.
For electricity generation with an Organic Rankine Cycle (ORC), heat is transferred to an organic working fluid. The vapour then flows through an expander that drives a generator, so that some of the recovered heat is converted into electricity. However, gross generation is not automatically equal to the net electrical contribution to the ship. The working-fluid pump, any intermediate-circuit pumps, additional cooling equipment and other necessary components may themselves consume electricity. It must therefore first be established how much net electricity the complete system actually supplies. The relevant auxiliary consumption and any electrical losses must be accounted for within a consistent system boundary.
The next step is to identify which existing generation this output displaces. When an ORC supplies electricity to the shipboard electrical system, one or more existing generating sets may produce less power. The fuel savings depend on how much less fuel those generating sets actually use. This change is not necessarily proportional to the amount of ORC electricity delivered, because a generating set's specific fuel consumption may change with engine load.
It also makes a difference whether a generating set is partially unloaded or can be taken out of service completely. The necessary electrical power reserve and the ship's safe operating strategy remain determining factors. A particular interaction arises when the ORC uses heat from the same generating set whose load is reduced by the ORC's electrical output. The lower engine load may also change that engine's exhaust gas and cooling-water heat, potentially leaving less heat available for the ORC.
Electrical output and fuel savings must then be determined at the resulting engine load. A calculation based solely on the original heat supply before the generating set was unloaded may overestimate the potential savings. Additional losses must also be included. An exhaust gas heat exchanger may, for example, cause additional back pressure, which under certain conditions affects engine operation and fuel consumption.
A similar assessment applies when the heat is used directly. When recovered heat reduces the load on an existing boiler or other heating system, it must be established how much less fuel that system actually uses as a result. Heat that already served a useful purpose before the new installation must be taken into account. When this heat is subsequently directed to an ORC and additional heating becomes necessary elsewhere, total fuel savings may be lower.
The common technical basis for EU ETS and FuelEU Maritime is therefore the difference in actual fuel consumption between sufficiently comparable conditions with and without waste heat recovery. Net energy output is an important starting point, but does not by itself establish how much fuel was saved. It must then be established which fuels are saved and during which voyages or port activities these savings arise. Only then can the effect be assessed under the separate European calculation rules.
How Does a WHRS Reduce the Emission Allowance Obligation Under EU ETS?
The maritime extension of the EU ETS is set out in Directive 2003/87/EC, as amended, inter alia, by Directive (EU) 2023/959. Since 2024, CO2 emissions from in-scope cargo and passenger ships of 5,000 GT and above have been covered by the emissions trading system. From the 2026 emissions year, methane (CH4) and nitrous oxide (N2O) are also included for these ships. These greenhouse gases are converted under the applicable rules into CO2 equivalents. The relevant emissions can thus be accounted for on a common basis when determining the allowances to be surrendered.
When a WHRS reduces fuel consumption, the associated emissions may decrease. The size of this reduction depends on the fuel actually saved, the engine installation concerned and the emissions that would have arisen without heat recovery. For a generating set running on a liquid fossil fuel, lower consumption may, for example, lead to lower CO2 emissions. For other engine and fuel configurations, changes in CH4 or N2O emissions may also be relevant.
The reduction must be determined under the applicable monitoring and emission factor rules. A general fuel savings percentage provides insufficient substantiation when there are insufficient data on the engine and its emissions. The EU ETS makes no separate allowance adjustment for fitting a WHRS. The possible reduction is reflected in the emissions determined and verified under the EU monitoring, reporting and verification rules.
Geographical scope is also a determining factor. For ships within scope, the scheme generally covers all relevant emissions from voyages between ports in the European Economic Area (EEA). It also generally covers all relevant emissions during stays at EEA ports. For voyages between an EEA port and a port outside it, 50% of the relevant emissions fall within the system in principle. The definition of a port of call applies, with exceptions or special provisions for certain voyages and activities.
The same fuel saving may therefore have a different effect on the emission allowance obligation on different routes. When a WHRS saves fuel during activities outside the geographical or other scope of the EU ETS, those savings do not automatically lead to fewer emission allowances having to be surrendered.
The phased introduction is also important. For the 2024 emissions year, 40% of emissions within the system had to be covered by emission allowances. For the 2025 emissions year, this share was 70%. From the 2026 emissions year, the surrender requirement covers 100% of the relevant emissions within scope for the ships concerned. Emission allowances for emissions during 2026 must be surrendered in 2027 by the applicable deadline.
This full phase-in does not mean that EU ETS automatically covers all emissions worldwide from a ship within scope from 2026 onwards. Geographical coverage and the other conditions of applicability remain determining factors. Further extension to other ship categories also has its own timetable. Offshore vessels of 5,000 GT and above are subject to the allowance surrender requirement from the 2027 emissions year under the applicable rules.
For a specific WHRS assessment, it must therefore first be established which emissions the ship actually avoids. It is then determined what proportion is subject to the applicable EU ETS surrender requirement. When fewer emission allowances consequently need to be surrendered, a financial benefit may arise alongside the fuel cost savings. Its value depends on the reduction in the relevant emission allowance obligation and the applicable value or cost of emission allowances.
The technical emissions effect and the final financial result must be determined separately. A given fuel saving does not necessarily yield the same financial ETS benefit on every voyage or in every ship configuration.
Why Does Lower Fuel Consumption Not Automatically Reduce FuelEU Intensity?
FuelEU Maritime assesses the annual average greenhouse gas intensity of the energy used on board within the scope of Regulation (EU) 2023/1805. This intensity is determined using the calculation method in Annex I to the regulation. The relevant Well-to-Tank and Tank-to-Wake emissions are included. The calculation covers, among other gases, CO2, CH4 and N2O, using the prescribed emission factors and any special calculation rules.
FuelEU Maritime uses a reference value of 91.16 g CO₂e/MJ. From 2025, the required reduction from this reference value is 2%. From 2030, the required reduction is 6%, after which the intensity limit is tightened further in later periods.
However, a waste heat recovery system does not automatically change the greenhouse gas intensity of the energy the ship uses. When an ORC supplies electricity and less fuel is consequently needed to run the existing generating sets, the amount of energy used from that fuel decreases. If the ship uses one fuel and the relevant emission factors remain the same, calculated greenhouse gas emissions and the energy used from that fuel both decrease. The ratio between emissions and energy used then remains the same.
The same principle applies when use of several energy sources falls in the same proportions and the other factors in the intensity calculation remain unchanged. Total emissions may therefore fall without average greenhouse gas intensity per megajoule changing. This is a fundamental difference from EU ETS. Under EU ETS, the relevant absolute emissions directly determine the quantity of emission allowances required. Under FuelEU Maritime, a reduction in absolute emissions does not automatically demonstrate that the average greenhouse gas intensity of the energy mix has fallen.
The electricity an ORC produces from engine heat already available must therefore not automatically be treated as a separate quantity of new zero-emission energy within the FuelEU energy mix. The technical benefit lies in avoiding additional fuel-fired energy production. This does not automatically change the applicable emission factor of the fuel the ship still uses. For the calculation, the energy actually used and the rules applicable to it must form the basis.
In its explanation of FuelEU Maritime, the European Commission explicitly distinguishes energy efficiency measures from technologies that can directly improve calculated greenhouse gas intensity. For certain other technologies, FuelEU Maritime contains specific calculation rules. Wind-assisted propulsion may, for example, provide a separate correction factor for the calculated intensity under the applicable conditions. Waste heat recovery does not automatically qualify for an equivalent factor.
A WHRS can therefore reduce the amount of fuel energy required while average FuelEU intensity remains the same. To achieve a lower intensity, changes in the energy carriers, their relative proportions or other specifically recognized measures may remain necessary.
How Can Waste Heat Recovery Still Change the FuelEU Compliance Balance?
Although a WHRS does not automatically lower greenhouse gas intensity when the energy mix remains the same, lower energy use may affect the FuelEU compliance balance. The balance is calculated under Annex IV to Regulation (EU) 2023/1805. The starting point is the difference between the greenhouse gas intensity limit for the year and the calculated annual average intensity. This difference is multiplied by the quantity of energy included in the calculation under the regulation.
The result is expressed in grams of CO2 equivalent and may be positive or negative. The sign and size of the balance therefore depend on both average intensity and the quantity of energy used. When average greenhouse gas intensity exceeds the applicable limit, a negative compliance balance arises. The ship then uses energy whose average intensity exceeds the permitted value.
When a WHRS reduces energy use under otherwise unchanged conditions while intensity remains above the limit, the same negative intensity difference is multiplied by a smaller amount of energy. The absolute size of the compliance deficit may consequently decrease. This is a possible benefit of waste heat recovery under FuelEU Maritime. However, the ship does not automatically meet the intensity requirement as a result, because average greenhouse gas intensity remains above the permitted value.
The situation is different when the ship has a positive compliance balance. A positive compliance balance arises when the calculated greenhouse gas intensity is below the applicable limit. When the ship subsequently uses less energy through waste heat recovery while average intensity remains the same, the same positive intensity difference is multiplied by a smaller amount of energy. The absolute size of the compliance surplus may consequently decrease.
That may seem contradictory, because the ship simultaneously uses less energy and produces fewer absolute greenhouse gas emissions. However, the explanation lies in the basis of the calculation. The positive balance represents how far the ship is below the greenhouse gas intensity limit, weighted by its energy use within FuelEU scope. When less energy is used, the size of that surplus may also become smaller.
This does not mean that energy efficiency or greenhouse gas intensity deteriorates. It is a consequence of the way the regulation calculates the compliance balance. The effect of the same energy savings therefore depends on the ship's starting position. With a negative balance, lower energy use may reduce the deficit, while with a positive balance the same savings may reduce the size of the available surplus.
The financial consequences also depend on this starting position. Under the applicable conditions, FuelEU Maritime allows ships to bank a surplus for the next reporting period, borrow an advance surplus from the next period or pool balances with other ships. A smaller deficit may reduce the shortfall that must be addressed through a flexibility mechanism or, ultimately, a FuelEU penalty. By contrast, a smaller positive balance may mean that less surplus remains available for banking or pooling.
Final compliance costs cannot be derived solely from the original compliance balance. The use of flexibility mechanisms, any previous balances and the other provisions of the regulation also play a role. Lower energy use must therefore not be translated into a fixed FuelEU saving in euros without further calculation. It must first be established how the lower quantity of energy affects the compliance balance and what that means for the ship's compliance position.
When Can an ORC Still Change FuelEU Greenhouse Gas Intensity Indirectly?
Waste heat recovery does not automatically lower FuelEU intensity, but may indirectly affect average greenhouse gas intensity under certain conditions. This is particularly relevant when ORC electricity does not reduce consumption of different energy carriers in the same proportions. A ship may, for example, use generating sets that run on a different fuel from the propulsion engine. When the ORC mainly replaces electricity production by these generating sets, their fuel's share of total energy use decreases.
The relative proportions of the fuels used consequently change. When these fuels have different applicable Well-to-Wake emission factors, the weighted average greenhouse gas intensity may also change. The direction of this effect depends on the energy source actually displaced. When the reduction mainly affects a relatively high-intensity energy source, the average intensity of the remaining energy mix may become more favourable.
If, instead, less fuel with a relatively low intensity is used while the share of another fuel with a higher intensity increases, the weighted average intensity may become less favourable. The WHRS's effect on FuelEU intensity is therefore not automatically positive. Engine type and the fuel configuration used may also be relevant. For certain emissions and fuel-consuming equipment, FuelEU Maritime uses specific calculation rules and emission factors.
For gaseous fuels, for example, the treatment of methane emissions and the applicable methane slip factors may depend on the engine design and the data used under the regulation. When ORC electricity changes which engines are used, this may also change the emissions attributable to the different engines. However, the result must be determined using the applicable FuelEU methodology.
A changed engine load or generator deployment does not mean that emission factors may be changed at the operator's discretion. The calculation must correspond to the fuels, engine configurations and other data relevant under the regulation. Other forms of energy used may also affect average intensity. When, for example, the amount of energy supplied by shore power remains the same while fuel consumption decreases, the relative proportions of the energy sources concerned may change.
The final intensity may consequently differ from the result when use of all energy sources falls proportionally. It must therefore be established for each energy carrier what quantity is actually reduced and how the relative proportions change as a result. The important distinction remains that any improvement or deterioration in FuelEU intensity arises from the changed energy mix or applicable emissions parameters. The ORC receives no automatic separate intensity discount for this.
Why Do the Emissions Accounting Bases and Geographical Scope Differ?
Alongside the distinction between absolute emissions and greenhouse gas intensity, EU ETS and FuelEU Maritime use different emissions accounting bases. The same fuel saving therefore does not necessarily lead to the same calculated quantity of CO2 equivalent under both systems.
EU ETS focuses on the greenhouse gas emissions that fall within the emissions trading system under the applicable European monitoring rules. For the cargo and passenger ships concerned, this has since 2024 included CO2 and, from the 2026 emissions year, also the relevant CH4 and N2O emissions. The basis is emissions from ship operations that are subject to the surrender requirement. The entire upstream fuel chain is not included in the emission allowance obligation in the same way as under FuelEU Maritime.
FuelEU Maritime, by contrast, uses a Well-to-Wake approach. Alongside emissions during use on board, the relevant greenhouse gas emissions from energy production, processing and supply are also included. EU ETS therefore concerns the relevant emissions that must be reported and covered under the emissions trading system. Under FuelEU Maritime, energy use is accounted for using the applicable life-cycle emission factors and the rules for the fuel or energy carrier concerned.
This difference is particularly important when a ship uses several fuels. A fuel may produce a particular quantity of CO2 or other greenhouse gases during combustion on board, while Well-to-Wake intensity is also affected by emissions from the upstream production chain. CH4 and N2O must therefore also be accounted for under the separate rules of the two systems. The same physical fuel savings may produce different calculated results under the two methods.
Geographical scope must also be distinguished. For EU ETS, voyages between ports within the European Economic Area are in principle covered in full. The relevant emissions during the relevant stay at an EEA port are also included in full in principle. Voyages between an EEA port and a port outside it generally have 50% of their relevant emissions covered. The applicable definitions of a port of call, exceptions and differing provisions remain determining factors for the specific assessment.
FuelEU Maritime uses a similar basic split. It generally covers 100% of the relevant energy used on voyages between ports within scope and during covered port stays, and 50% on voyages between a port within scope and one outside it. However, the geographical scope in November 2026 is not entirely the same as for EU ETS. The FuelEU Maritime regulation has not yet been incorporated into the EEA Agreement for Norway and Iceland.
The ports in these countries are therefore treated as third-country ports for FuelEU Maritime purposes during this period. The Norwegian Maritime Authority announced in August 2026 that FuelEU Maritime would not enter into force in Norway before 1 January 2028. In the meantime, FuelEU Maritime generally covers 50% of the relevant energy used on voyages between an EU port and a Norwegian or Icelandic port. A voyage between two Norwegian ports falls outside that scope during this period.
For EU ETS, by contrast, Norway and Iceland are treated within the EEA framework because the relevant emissions trading and MRV rules have been incorporated into the EEA Agreement. The same voyage may therefore have different geographical coverage under EU ETS and FuelEU Maritime. The definitions of a port of call, certain exceptions and the treatment of specific ship activities may also differ. It must also be established for each ship whether it meets the ship and activity criteria for both systems.
Not every ocean-going or coastal vessel is automatically subject to both regulatory frameworks. The assessment of WHRS savings must therefore establish for each system which fuel or energy falls within the relevant scope. Without this breakdown, worldwide annual fuel consumption does not form a sufficient basis for both calculations. The emissions accounting basis and geographical coverage must be applied separately before the effect of the fuel saving can be established.
How Do You Prevent Double Counting When Assessing WHRS Savings?
The fuel actually saved provides the common technical basis for assessing waste heat recovery under EU ETS and FuelEU Maritime. However, this does not mean that the results of the two regulatory calculations may be added together as two separate physical emission reductions.
The assessment starts by establishing the net energy that the WHRS actually delivers to the ship. For electricity generation, gross generation is accounted for separately from the system's own electricity consumption and electrical losses. For direct heat use, it is established how much useful thermal energy is actually delivered to the equipment that uses it. In both cases, it must be clear which energy was already used and how much additional energy the new installation makes available.
It is then determined which existing generation the recovered energy can displace. When an ORC supplies electricity that would otherwise be generated by a generating set, the difference in that generating set's fuel consumption is established. This comparison must take place under sufficiently comparable operating conditions. Changes in ship speed, electrical demand or engine dispatch must not be treated as savings from the WHRS without further substantiation.
The effect of heat recovery on the original heat source must also be included. When ORC generation reduces the load on a generating set, the engine may release less waste heat. The ORC's electricity production may consequently also change. Any additional losses from heat exchangers and auxiliary equipment must also be accounted for. Existing heat demands must still be accounted for when the heat they originally used is subsequently used for electricity production.
This gives a supported estimate of the fuel saved, broken down by fuel type and operating period. These technical data can then serve as the common basis for two separate regulatory calculations. For EU ETS, it is determined which relevant greenhouse gas emissions have been avoided through the fuel savings and what proportion falls within the emissions trading system. For FuelEU Maritime, it is established how much of the energy used falls within the regulation's scope and whether the change in fuel consumption affects average greenhouse gas intensity.
Any change in the compliance balance is then calculated using the prescribed method. The same fuel savings may therefore be relevant under both regulatory frameworks without necessarily resulting in double counting. The systems impose different legal obligations, after all. However, it must be ensured that the same avoided emissions are not presented as two separate physical emission reductions.
Net ORC electricity must also not be added again to the FuelEU calculation as a separate quantity of zero-emission energy without a legal basis when the fuel savings have already been accounted for correctly. The same principle applies to auxiliary consumption. Electricity consumption already included in net WHRS output must not be deducted again. Conversely, necessary additional pumps or cooling equipment still outside the energy balance must not be ignored.
In the financial assessment too, a clear distinction must be made between the different effects. Avoided fuel costs, a possible reduction in ETS costs and any effects on FuelEU compliance costs may be distinct financial effects of the same measure. These amounts can be examined in a business case, but only when each calculation has been performed correctly and the same costs or savings are not included twice.
For FuelEU Maritime, the original compliance position must be taken into account. A smaller positive balance may, for example, have a different economic significance from a smaller negative balance. Banking, borrowing and pooling may also affect the final financial result.
Official reporting and verification remain authoritative. For EU ETS, emissions are determined under the applicable monitoring, reporting and verification requirements. For FuelEU Maritime, energy use, greenhouse gas intensity and the compliance balance are determined and verified under its own regulation. An internal calculation of WHRS savings can support both assessments, but does not replace the prescribed reporting or verification.
By using the same technical data on fuel avoided as the starting point and then applying the separate statutory calculations, the different outcomes can be explained. At the same time, physical emissions reductions, electrical energy output and compliance benefits can be kept separate.
What Does the Difference Between EU ETS and FuelEU Maritime Mean for a WHRS?
Waste heat recovery may have value under both European regulatory frameworks, but that value arises in different ways. Under EU ETS, the main effect is that avoiding greenhouse gas emissions covered by the system can reduce the number of allowances to be surrendered. The size of this reduction depends on the fuel saved and the associated emissions avoided, the voyages and port activities concerned and the applicable ETS rules. The final financial benefit must also be determined separately.
Under FuelEU Maritime, the focus is on the average greenhouse gas intensity of the energy used within the scope. When a WHRS reduces fuel use without changing the relative shares of the energy sources or their applicable emission factors, this average intensity in principle remains the same.
However, total energy use decreases, so the size of the FuelEU compliance balance may change. With a negative compliance balance, lower energy use may reduce the deficit. With a positive balance, the same reduction in energy use may instead lead to a smaller available surplus.
When the ORC does not reduce consumption of different fuels in the same proportions, the weighted average FuelEU intensity may also change. The direction and size of that effect must be determined from the actual energy mix and applicable emission factors.
The two systems may also have different geographical coverage. Particularly for voyages to and from Norway or Iceland, this is relevant in November 2026 because FuelEU Maritime does not yet apply there in the same way as EU ETS.
These differences are important in assessing the overall contribution of waste heat recovery. An ORC that demonstrably saves fuel may reduce absolute emissions and the ETS obligation, while additional measures may remain necessary to meet the FuelEU intensity limit.
Conversely, the absence of a direct improvement in FuelEU intensity does not mean that the WHRS savings have no significance under this regulation. Lower energy use may affect the compliance balance and have financial consequences, depending on the starting position and the flexibility mechanisms used.
The assessment must therefore always start with the fuel actually saved and the effects on the ship's energy system as a whole. The net electrical or thermal contribution of the WHRS is distinguished from the fuel savings achieved under sufficiently comparable operating conditions.
The relevant emissions for EU ETS and the energy used, greenhouse gas intensity and compliance balance for FuelEU Maritime are then determined under their separate rules.
It thus becomes clear why the same waste heat recovery may directly affect the quantity of emission allowances required under EU ETS, while the effect under FuelEU Maritime depends on energy use, the composition of the energy mix and the existing compliance balance.
The underlying fuel savings are the same in both cases. The difference arises from the emissions accounting bases, geographical scope and calculation methods by which the two European regulatory frameworks assess these savings.
This Article Within the Series
A WHRS may reduce emissions and thus the obligation under EU ETS without average greenhouse gas intensity under FuelEU Maritime automatically falling. This distinction relates to tracking the WHRS contribution to CII through the SEEMP, where actual fuel consumption is also a determining factor. How avoided fuel costs, ETS costs and possible FuelEU effects are reflected financially is discussed under the economic viability of waste heat recovery. These different assessment frameworks form part of the regulation and assessment of WHRS installations.